													 Junction Box for Easy Connection to ServoStep™ or MAC motor® 
																 
													Plug-and-play Junction Box for standard M8-3pin sensors and devices. Just connect the Junction Box to your integrated servo or stepper motor and up to 8 local 24 VDC I/Os are available 
													  
													Connected I/Os can be read or set from the motors embedded ePLC™ program or via Industrial Ethernet. WI1302 offers easy connection of standard 3-pin M8 connectors typically used for limit switches and home sensor. All the 8 I/Os are available on separate M8 connectors, making it extremely easy to integrate and connect MAC motor® and ServoStep™ into any machine. 
														 
													  
													Details: 
													
														
															- Power LED
 
															- LEDs for easy monitoring of I/O states
 
															- Built-in 24 VDC supply for sensors
 
															- 8 x M8-3pin Female connectors
 
															- M12-17pin Male connector for the connection to JVL motor
 
															- 1 meter shielded cable
 
															- IP67 rated
 
															- Multiple mounting options
 
															- Automatic output supply when used with ServoStep™ or SMC 66/85 controllers
 
															- Output supply must be provided when used with MAC motor® - see below 
 
														  
													   | 
											 
										
									  | 
							 
						
					   | 
			
				    | 
			  
				 | 
			  
				 | 
			  
				 | 
			  
				 | 
		
		
			  
				 | 
		
	
 
Connections – ServoStep™ or SMC66/85 
	
		
			
				  | 
				
					 Connect sensors and other I/Os according to this diagram, where Female pins are seen from the top of the WI1302.  
					 | 
			
		
	
 
	
Connections – Ex41 Ethernet module for MAC motor® 
	
		
			
				  | 
				Connect sensors and other I/Os according to this diagram, where Female pins are seen from the top of the WI1302. 
					NB! WI1302 cannot be used with MAC00-Ex4 modules, ONLY with MAC00-Ex41 modules. | 
			
		
	
 
 
If WI1302 is used together with a MAC00-Ex41 Ethernet module for MAC motor® then output supply must be provided in one of two ways
	
		- Connect external 24 VDC supply using AI2 (I/O8) or AI1 (I/O7) because AI1 and AI2 can't be used anyway due to the isolation.
 
		- Set the DIP switches on the Ex41 module to ON – se below.   AI1 and AI2 works with this setup.
 
	
 
	
 