Color code of the internal connections in the MIS23x.
 
 
Color code of the internal connections in the MIS23x.
 
 
The outside connections can be found in the manual, but if the internal connections are needed, then you have to find them here.
 
J2 ( Power connector )
Cable:  WG0803
1.  Red          ; P+
2.  Blue         ; CVI 
3.  Black        ; P-
 
J3 ( IO1-4, RS422 ( A+, A- ) and RS485 )
Cable:  WG0801
1.   White        ; IO1
2.   Brown       ; IO2
3.   Green       ; IO3
4.   Blue          ; IO4
5.   Red           ; CVO
6.   Orange      ; RS485 - A-
7.   Grey         ; RS485 - B+
8.   Yellow       ; Gnd
9.   NC            ; ( RS422 - A1+ )
10. NC            ; ( RS422 - A1+ )
 
J4 ( IO5-8, RS422 ( B+, B- )
Cable:  WG0806
1.   White        ; IO5
2.   Brown       ; IO6
3.   Green       ; IO7
4.   Blue         ; IO8
5.   Red          ; CVO
6.   NC           ;
7.   NC           ;
8.   Yellow      ; Gnd
9.   NC           ; ( RS422 - B1+ ) 
10. NC           ; ( RS422 - B1- )
 
J5  ( CAN )
Cable:  WG0802
1.  NC            ; ( Gnd )
2.  White        ; Gnd
3.  Grey         ; CAN_H
4.  Black        ; CAN_L
5.  Blue          ; V+
6.  Brown       ; Gnd
 
 
 
 



JVL A/S Bregnerødvej 127 DK-3460 Birkerød Denmark
Tel: +45 4582 4440 Fax: +45 4582 5550 E-mail: jvl@jvl.dk